Setting The Ir Channel - Gefen Multiview EXT-HD-MVSL-441 User Manual

Seamless switcher
Hide thumbs Also See for Multiview EXT-HD-MVSL-441:
Table of Contents

Advertisement

Getting Started
Chapter
NOTE: The IR remote must be set to channel 0 in order to
communicate with the 4x1 Multiview Seamless Switcher for HDMI.
Make sure that the IR remote is set to channel 0 (see the diagram, below). Otherwise, the
switcher will not work with the IR remote. Future releases of the firmware will allow the IR
channel to be changed.

Setting the IR Channel

DIP switches
page | 8
IR Remote Control Unit
IR Channel
DIP settings
0
ON
1
2
1
ON
(not used)
1
1
2
2
2
ON
(not used)
1
2
3
ON
(not used)
1
2

Hide quick links: