Specific Projector In A Network With One Controller; Specific Projector In A Network With Multiple Controllers; What Is Actually Sent In A Message - Christie Mirage WQ-L User Manual

Data projector
Table of Contents

Advertisement

Specific Projector in a Network with one Controller

Message Format
(Dest Addr Code Data)
($Dest Addr Code Data)

Specific Projector in a Network with Multiple Controllers

Message Format
(Dest Addr
Src Code?)
($Dest Addr
Src Code Data)
(Dest Addr
Src Code!Data)

What is Actually Sent in a Message?

Although you will send and read messages as strings of ASCII characters, the actual message
travels as a sequence of bytes. Each character in this sequence requires one byte. The example
below illustrates a "gamma function 222" reply from the projector.
ASCII =
(
HEX =
0x28
Mirage WQ-L User Manual
020-101372-01 Rev. 1 (04-2014)
Function
SET (turn projector #5 on)
SET AND ACKNOWLEDGE MESSAGE (message
processed?ffr55)
Function
REQUEST (get gamma function from projector #5 to
controller #2)
SET AND ACKNOWLEDGE MESSAGE (is message from
controller #2 processed by projector #5)
REPLY (from projector #5 to controller #2: gamma
function is 222)
B
G
F
0x42
0x47
0x46
!
2
2
0x21
0x32
0x32
Serial Communication
Example
(5pwr1)
($5pwr1)
Example
(5 2BGF?)
($5 2BGF?)
(002 005BFG!222)
2
)
0x32
0x29
68