Gamma Correction (Gam); General Purpose Input/Output (Gio); Serial Help (Hlp) - Christie Mirage WQ-L User Manual

Data projector
Table of Contents

Advertisement

Gamma Correction (GAM)

GAM
Preference
CONTROL GROUP:
Description
The Gamma Correction control is used to correct ambient conditions affecting the display. The Gamma control
affects the shape of the curve determining what grey shades are displayed for a given amount of signal Input
between minimum (black) and maximum (white). This is done by performing a linear transform from the user
selected gamma setting. The normal point is 0, meaning the selected gamma table is used unaltered. If there is a
lot of ambient light, the image can become washed out, making it difficult or impossible to see details in dark
areas. Increasing the gamma correction setting can compensate for this by transforming the curve towards a
gamma of 1.0. Decreasing the control shall transform the gamma towards a gamma of 3.0.
See
Base Gamma Curve (BGC)
See
Base Gamma Function (BGF)
See
Base Gamma Slope (BGS)
Subcode
<No Subcode >
Examples:
(GAM 100) Set gamma to 1.0 curve. 
(GAM?) Returns current gamma curve.

General Purpose Input/Output (GIO)

GIO
Config
CONTROL GROUP:
Description
Control or monitor the state of the General Purpose Inputs and Outputs. 
The strings have one character for each hardware connector pin, and from left to right, correspond to the pin
numbers 2,3,4,6,7,8,9. (Pin 1 is 12V and Pin 5 is Ground - they cannot be read, set or configured).
A low state (or value of 0) will be read on an Input pin if the circuit attached to the pin is open. A high state (or
value of 1) will be read on an Input pin if the circuit attached to the pin is shorted to ground. This corresponds to
a switch closing event.
Subcode
CNFG
STAT
Examples:
(GIO+STAT?) Get status of all the Inputs. Returns (GIO+STAT!"0000000") - All Inputs are low. 
(GIO+STAT "1x01000") Set status of the GPOs - 2 high, 3 no change, 4 Low, 6 High, 7 Low, 8 Low, 9 Low. 
(GIO+STAT "hxxlxxx" 500) Set status of the GPOs - 2 Pulse high, 6 Pulse Low. Use interval of 500 ms for each. 
(GIO+CNFG "IIOOOIO") Set pins 2, 3 and 8 to Input, 4, 6, 7 and 9 to Output.

Serial Help (HLP)

HLP
Unsaved
CONTROL GROUP:
Description
Query a list of all available serial commands, with brief descriptions and current enabled states.
Mirage WQ-L User Manual
020-101372-01 Rev. 1 (04-2014)
Power Up
SUBCLASS:
on page 78.
on page 78.
on page 79.
Description of Use
Set the interpolated gamma level
Power Down
SUBCLASS:
Description of Use
Set the Direction for the individual pins to Inputs or outputs.
Get the state of all Inputs, or set the state of all outputs.
Power Down
SUBCLASS:
Serial Command Reference
Operator
ACCESS LEVEL:
.
Advanced
ACCESS LEVEL:
Operator
ACCESS LEVEL:
84