Select a Test Pattern
1. From the Test Pattern drop-down select the desired internal test pattern or select Off to
disable.
Set Grey Level
Use the slide bar to set the level of grey for displaying in the full grey field test pattern.
Freeze Light Engine Image
Check this option to freeze an incoming image on a single frame in order to examine details. 
For example, in moving images it is sometimes difficult to observe artifacts such as external 
de-interlacing/resizing and signal noise. Uncheck to return to normal.
Select a Color
From the Color Enable drop-down select a color while working with color temperature, input levels
or other setup parameters.
Select a Light Engine Test Pattern
From this drop-down select 1 of four light module test patterns. Choose from White, Grey Scale
16, Horizontal Ramp, No Test Pattern.

Upgrade Software

The upgrade package is a single file, which comprises all the firmware and software needed to
operate the projector. The upgrade process updates the firmware files as necessary. Hardware that
is up-to-date is not upgraded.

Requirements

Version: 1.0.0 or higher
Internet Explorer 6.0/7.0 (IE7 is recommended)
Ethernet connection to projector
Workstation that can connect to the projector via Ethernet
It is recommended to be in Standby Mode before starting the upgrade procedure.
1. Apply power to projector.
2. Open Internet Explorer and browse to http://<ipaddress> where <ipaddress> is the IP
address of the projector. The login screen appears.
3. Log in using the admin account. If you are unable to login under admin it may be that the
password has been changed. Check with the projector maintainer for the correct password.
4. Select the Admin tab.
Mirage WQ-L User Manual
020-101372-01 Rev. 1 (04-2014)
Operation
52