Christie Mirage WQ-L User Manual page 37

Data projector
Table of Contents

Advertisement

Add a Scheduled Event
Scheduled events include a command or sequence of commands, for example, (PWR1) or (PWR1)
(LSH1).
1. From the Advanced tab, click Add to open the RTE Wizard.
2. Select the Scheduled Event tab.
3. Select the frequency option for the event by selecting either Once, Daily, Weekly, or
Monthly. End Date is enabled when Daily, Weekly or Monthly repeat options are selected.
Depending on the selected frequency option, a related Repeat Every is highlighted on the tab.
Use this area to enter the frequency of each event.
4. Click within the Start Time field to open a calendar pop-up window.
5. Navigate to and choose the desired date. The selected date will populate the Start Time field.
6. In the field below the Start Time field, enter a start time in the format "hr:min:sec". The
setting defaults to the current time.
7. Click Sync to set the computer and projector time to be the same; otherwise, the event will run
based on the projector time.
8. Enter a description of the scheduled event in the Description field.
9. Enter a serial command or a sequence of serial commands, with which you wish the projector to
perform in the Command String field.
10. If a GPIO command string is needed, click the GPIO Output Helper button for instructions on
how to create the command structure. The Output field contains seven blocks which refer to
the seven I/O pins on the GPIO connector. 
Pin 1 = +12V and Pin 5 = Ground. These are not included. Clicking a block toggles between H,
L, and X. See
Click Help for a description of special RTE commands available for adding loops and delays to
the command sequence.
11. Click Test to run the entered command string. A green or red icon appears to the right side of
the Test button to indicate whether the test passed or failed.
12. Click Finish to create the added event. The added event appears in the RTE Listing window. To
activate or deactivate one or more RTEs listed in the window, select or clear each check box in
the Active column.
Add a System Event
1. From the Advanced tab, click Add to open the RTE Wizard.
2. Select the System Event tab.
3. Select a type of event from the System Event drop-down list.
Depending on the selection made, additional selections are available in the second drop-down
list located underneath (i.e. Input Change # > Slot 1, Input 1).
Mirage WQ-L User Manual
020-101372-01 Rev. 1 (04-2014)
Serial Communication
on page 63 for details.