Status Display; Error Codes - Christie Mirage WQ-L User Manual

Data projector
Table of Contents

Advertisement

Status Display

Projector status is indicated by a single three-color LED adjacent to a two-digit status display. Refer
to the table below for a description of the variations that indicate operation status. A solid red LED
indicates a system error and the corresponding error code indicates what the error is.
Status
Two-Character Display
Rotating

Solid Yellow
PR (Programming Time)
FS (Failsafe mode)
— —
— —
• BO (Booting) when power first applied.

Solid Green
• B1 (Boot phase 1) starting main script
• B2 (Boot phase 2) starting projector code
• B3 (Boot phase 3) about to initialize
SH (Shutter Mode)

Flashing Green
System error.

See
Solid Red
blank
Rotating

Error Codes

If the status display window shows any of the codes in the table below you may need a Christie
accredited service technician to repair the component identified by the error code.
Error codes are displayed in a three-phase format:
First two digits represent the component or error category
Second two digits represent the specific problem
Display off
This cycle repeats. The LED will be red while the error code is displayed.
Mirage WQ-L User Manual
020-101372-01 Rev. 1 (04-2014)
, static
, moving up and down
connections
Error Codes
on page 59.
Troubleshooting
Description
Warming up.
The projector is in Failsafe mode. See
Upgrade Software
on page 52.
Standby mode.
Brief cool down period.
LEDs are disabled to shutter the projector.
Keypad command sent — command received.
Initializing hardware and performing Power
On Self Test.
59

Advertisement

Table of Contents
loading

Table of Contents