4-3 IP network connection EXT Input (EXT IN)

ï IP network connection setting
Set the signal destination from the external equipment through the [IN] port, in this
screen.
Place the mouse pointer on "Connection setting," and then on "IP network connec-
tion," and then click "EXT Input (EXT IN)" shown on the list.
q
w
e
r
t
• The above setting screen is only displayed when you set "IP communication mode setting" to
"Multicast mode." (p. 123)
• You cannot set these settings when "During transmit" is displayed in the status field of "IP net-
work connection status."
• The default settings (q–t) are dependent on "IP communication mode setting."
q Connection IP address
Set the destination VE-PG2's IP address.
(Default: Multicast mode: 239.255.255.1, Unicast mode: Blank)
• When you set "IP communication mode setting" to "Multicast mode," set the IP address to be-
tween "224.0.0.0" and "239.255.255.255."
To operate the VE-PG2 in the Multicast mode, set ALL the VE-PG2s' Connection IP address
to same address.
• When you set "IP communication mode setting" to "Unicast mode," set the destination VE-
PG2's IP address.
You can also set a domain name (up to 63 characters) instead of the IP address.
w Connection port number
Set the destination VE-PG2's port number.
(Default: Multicast mode:22510, Unicast mode: 21506)
• You can set the port number to between 2 and 65534 (even numbers only).
e My station port number
Set the VE-PG2's communication port number.
(Default: Multicast mode:22510, Unicast mode: 21506)
• You can set the port number to between 2 and 65534 (even numbers only).
• DO NOT set the same port number to [TRX1]–[TRX3], [IN] or [OUT].