6
CONVERTER MODE SETTING SCREEN
9. [Port Settings] Menu (continued)

M EXT Control Terminal (EXT Output)

Set the details of the control signal from the[ EXT1]/[EXT2] port.
• These items appear when [Relay Circuit] is selected in [Control Circuit Switching].
q Control Output at the Start of Audio Output
w EXT Control Output Pattern
e Event ON Time ...............
rEvent OFF Time ............
Select "Enable" to output the control signal when the audio signal is output.
(Default: Enable)
Select the control signal input condition.
• Momentary
Connects the B1/B2 terminals (Relay circuit) only while the event is
detected.
• One-shot
Connects the B1/B2 terminals (Relay circuit) while the event is detected for
the time period set in [Event ON time] (e).
• Disconnects the terminals after the time period set in [Event OFF Time]
(r) has passed.
Select the delay time until the event is detected.
Select the delay time until the B1/B2 terminals (Relay circuit) is disconnected.
6-92
[Port Settings]–[EXT Output 1 (EXT1)/
EXT Output 2 (EXT2)]
(Default: Momentary)
(Default: 1)
(Default: 1)