Ip Network Connection Ext Output (Ext Out) - Icom VE-PG2 Instruction Manual

Roip gateway
Hide thumbs Also See for VE-PG2:
Table of Contents

Advertisement

4-4 IP network connection EXT Output (EXT OUT)

ï IP network connection setting
Set the signal destination from the external equipment through the [OUT] port, in
this screen.
Place the mouse pointer on "Connection setting," and then on "IP network connec-
tion," and then click "EXT Output (EXT OUT)" shown on the list.
q
w
e
r
• The above setting screen is only displayed when you set "IP communication mode setting" to
"Multicast mode." (p. 124)
• You cannot set these settings when "During receive" is displayed in the status field of "IP net-
work connection status."
• The default settings (q–r) are dependent on "IP communication mode setting."
q Connection IP address
Set the destination VE-PG2's IP address.
(Default: Multicast mode: 239.255.255.1, Unicast mode: Blank)
• When "IP communication mode setting" is set to "Multicast mode," set the IP address to
"224.0.0.0"–"239.255.255.255."
To operate the VE-PG2 in the Multicast mode, set ALL the VE-PG2s' Connection IP address
to same address.
• When "IP communication mode setting" is set to "Unicast mode," set the destination VE-PG2's
IP address.
You can also set domain name (up to 63 characters) instead of the IP address.
w Connection port number
Set the destination VE-PG2's port number.
(Default: Multicast mode: 22510, Unicast mode: 21508)
• You can set the port number to between 2 and 65534 (even numbers only).
e My station port number
Set the VE-PG2's communication port number.
(Default: Multicast mode: 22510, Unicast mode: 21508)
• You can set the port number to between 2 and 65534 (even numbers only).
• DO NOT set the same port number to [TRX1]–[TRX3], [IN] or [OUT].
BRIDGE MODE SETTING SCREEN
4
1
2
3
4
5
6
7
8
9
10
11
133