2
SELECTIVE CALL MODE APPLICATION
■ Using with an in-house sound system (Continued)
Step 8 Operation
q Turn ON transceiver 2's power, and set the same operating channel as trans-
ceiver 1.
w Hold down transceiver 2's [PTT], and then push [4] and [#] to transmit DTMF sig-
nals.
e When the VE-PG2 receives the DTMF signals, it fades out the in-house sound,
and sends the "Broadcast start sound" to the external amplifier.
r Hold down transceiver 2's [PTT] and talk into the microphone to make an an-
nouncement.
t When the VE-PG2 receives # DTMF signal or no sound for the preset time (de-
fault: 15 seconds), send "Broadcast end sound" to the external amplifier, and then
fades in the in-house sound.
Other transceivers
Transceiver 2
Turn ON the transceivers' power,
and then set transceiver 1's
volume control to the 12 o'clock
position.
28
CAUTION:
To connect the transceivers or repeaters, use only the following cables:
OPC-2073 (For the transceivers) or OPC-2074 (For the repeaters).
Connect the specified cables to only [TRX1], [TRX2] or [TRX3].
Using another cable, like an Ethernet cable, may damage the VE-PG2,
transceivers or repeaters.
[TRX1]
Connect to transceiver 1's speaker jack.
Transceiver 1
[TRX1]
Call destination number: 4
External
amplifier
[OUT]
VE-PG2
192.168.0.2
NOTE: First, connect the transceiver
to the VE-PG2 using the optional
OPC-2073. Then turn ON the power
to the transceiver and the VE-PG2.
For in-house sound (BGM)
External
device
[IN]