Ip Network Connection Transceiver 1 (Trx1)-Transceiver 3 (Trx3) - Icom VE-PG2 Instruction Manual

Roip gateway
Hide thumbs Also See for VE-PG2:
Table of Contents

Advertisement

4-2 IP network connection Transceiver 1 (TRX1)–Transceiver 3 (TRX3)
ï IP network connection setting
Set the [TRX1]–[TRX3] port network setting for operation in Bridge mode.
Place the mouse pointer on "Connection setting," and then on "IP network
connection," and then click on one of the Transceiver ports, TRX1, TRX2 or TRX3
shown on the list.
q
w
e
r
t
• The above setting screen is only displayed when you set "IP communication mode setting" to
"Multicast mode." (p. 123)
• You cannot set these settings when "During transmit" or "During receive" is displayed in the
status field of "IP network connection status."
• The default settings (q–t) are dependent on "IP communication mode setting."
q Connection IP address
Set the destination VE-PG2's IP address.
(Default: Multicast mode: 239.255.255.1, Unicast mode*: Blank)
[NOTE]
• When you set "IP communication mode setting" (p. 123) to "Multicast mode," set the IP
address to "224.0.0.0"–"239.255.255.255."
To operate the VE-PG2 in the Multicast mode, set ALL the VE-PG2s' Connection IP address
to same address.
• When you set "IP communication mode setting" to "Unicast mode," set the destination
VE-PG2's IP address.
You can also set a domain name (up to 63 characters) instead of the IP address.
w Connection port number
Set the destination VE-PG2's port number.
(Default: Multicast mode:22510, Unicast mode: [TRX1] is 21500, [TRX2] is 21502
and [TRX3] is 21504)
• You can set the port number to between 2 and 65534 (even numbers only).
BRIDGE MODE SETTING SCREEN
4
1
2
3
4
5
6
7
8
9
10
11
125

Advertisement

Table of Contents
loading

Table of Contents