SELECTIVE CALL MODE SETTING SCREEN

5-16 Abnormal condition monitor

ï Monitor function setting
Set the monitor function when the communication error occurs.
Place the mouse pointer on "Connection setting," and then click "Abnormal condition
monitor" shown on the list.
q
w
q LAN port downlink
When the Ethernet cable disconnects from the VE-PG2's the [LAN] port, the [LAN]
indicator blinks red, and the error message is displayed on "SYSLOG" in "Information."
• When you check the "LAN port downlink" check box, the "EXT Output" radio button as below
appears.
• If you check the "EXT Output" radio button to "Enable," the VE-PG2 sends the signal to [OUT]
port when the communication error occurs.
• When "Use control output" is set to "Enable," the error detect signal is sent to the [A], [B] and
[C] ports.
• While the error detect signal is sent, the VE-PG2 cannot receive signals from the external de-
vice that is connected to the [IN] port.
(Check box default
(Radio button default : Disable)
w PING transmitting error to appointment host
The VE-PG2 automatically sends PING commands to the specified IP address.
• When you check the "PING transmitting error to appointment host" check box, "EXT Output"
radio buttons and IP address and Monitor period as below appear.
• If you check the "EXT Output" radio button to "Enable," the VE-PG2 sends the signal to the
[OUT] port when the PING error occurs.
• The PING command send interval and specified IP address can be set in the same screen.
• When the PING error occurs, the [LAN] indicator blinks alternately red and green, and the
error message is displayed on "SYSLOG" in "Information."
• When "Use control output" is set to "Enable," the error detect signal is sent to the [A], [B] and
[C] ports.
• While the error detect signal is sent, the VE-PG2 cannot receive signal from the external de-
vice that is connected to the [IN] port.
(Check box default
(IP address default
(Radio button default
(Monitor period default
(Monitor period selectable range : 1 to 4320 (minutes))
: o LAN port downlink)
: o PING transmitting error to appointment host)
: Blank)
: Disable)
: 10 (minutes))