Noise Level; Data Reg. The Electrical And Hydraulic Equipment; Dimensions, Technical Data, Installation Instructions - Meiko FV 40.2 Operating Instructions Manual

Dish- and glasswashing machine
Table of Contents

Advertisement

Operating instructions FV 40.2 / FV 40.2 G / FV 60.2
IMPORTANT!
Datei:1_FV40_60-2_9546822_Betriebsanleitung_EN_2004-03.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
Both method makes it possible to achieve disinfection levels higher than the standard
(e.g. in hospitals).
The tank temperature falls when the programme begins, depending on the washware.
The time needed to reach the set disinfection parameters could exceed the set
programme time.
High washing temperatures and long retention times in the wash tank can lead to glass
corrosion and premature peeling of the decor.
11.1.5 Detergent dosage
The detergent dosing unit (option) is designed for the automatic adding of liquid, alkaline
detergent into the wash water.
The detergent is transported out of the container into the wash tank by means of a hose
line. The dosing unit is self-priming. The dosing is effected during each filling cycle and
at the beginning of each programme cycle using timer control.
Normally, a dosing of approx. 2 ml of detergent per liter of tank water is the correct
concentration. This can be increased/reduced acc. to the water quality, items to be
washed and degree of soiling to 5 ml/l or to1 ml/l.
11.1.6 Rinse aid dosing
The rinse aid dosing unit is designed to automatically add liquid final rinse aid into the
fresh water.
The rinse aid is transported out of the container into the fresh water supply line by means
of a hose line. The dosing unit is self-priming. The dosing takes place during each filling
cycle.
The correct dosing results in a smooth, even water film.
In case of overdosing, there are bubble and stripe formations - reduce dosing.
In case of under-dosing, water drops remain on the washed items - increase dosing.

11.2 Noise level

Work place noise level LpA £ 70 dB

11.3 Data reg. the electrical and hydraulic equipment

See attached technical sheet

11.4 Dimensions, technical data, installation instructions

See attached technical sheet
Update: 2008-03-10
W e reserve the right to change execution and construction!
S. „FV 40 G"
20/42
9544094

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fv 60.2

Table of Contents