12.1.2 Detergent dosing
The detergent dosing unit is designed for the automatic addition of liquid alkaline deter-
gent to the clean water.
The detergent is transported out of the container into the clean tank by means of a hose
line. The dosing equipment is self-priming. Dosing occurs during each filling cycle and at
the beginning of each program cycle via timer control.
Normally, a dosing of approx. 2 ml of detergent per liter of tank water is the correct
concentration. This can be increased/reduced acc. to the water quality, items to be
washed and degree of soiling to 5 ml/l or to1 ml/l.
12.1.3 Rinse aid dosing
The rinse aid dosing unit is designed to automatically admix liquid final rinse aid into the
fresh water.
The rinse aid is pumped out of the storage container into the fresh water supply line
through a hose. The dosing equipment is self-priming. Dosing takes place during each
filling cycle.
The correct dosing results in a smooth, even water film.
In case of overdosing, there are bubble and stripe formations - reduce dosing.
In case of under-dosing, water drops remain on the washed items - increase dosing.

12.2 Noise emission

Work place noise level L
£ 70 dB
pA

12.3 Electrical and hydraulic equipment data

See attached technical sheet
12.4

Dimensions, technical data, installation instructions

See attached technical sheet
13

Non-ionising radiation

Non-ionising radiation is not produced intentionally but unfortunately comes about due to
electrical operating equipment (e.g. electrical motors, high-voltage cables and magnetic
coils).
In addition the machine has no strong permanent magnet. There is a high possibility of
eliminating any influence on active implants (e.g. pacers, defibrillators) by maintaining a
safety distance of 30 cm (distance of the field source to the implant).