Noise Level; Data Reg. The Electrical And Hydraulic Equipment; Dimensions, Technical Data, Installation Instructions; Ec-/Eu-Declaraton Of Conformity - Meiko FV 28G Operating Instructions Manual

Universal warewashing machine
Table of Contents

Advertisement

10.1.6 Detergent dosage
The detergent dosing unit (option) is designed for the automatic adding of liquid, alkaline
detergent into the wash water.
The detergent is transported out of the container into the wash tank by means of a hose
line. The dosing unit is self-priming. The dosing is effected during each filling cycle and at
the beginning of each programme cycle using timer control.
Normally, a dosing of approx. 2 ml of detergent per liter of tank water is the correct con-
centration. This can be increased/reduced acc. to the water quality, items to be washed
and degree of soiling to 5 ml/l or to1 ml/l.
10.1.7 Rinse aid dosing
The rinse aid dosing unit is designed to automatically add liquid final rinse aid into the
fresh water.
The rinse aid is transported out of the container into the fresh water supply line by means
of a hose line. The dosing unit is self-priming. The dosing takes place during each filling
cycle.
The correct dosing results in a smooth, even water film.
In case of overdosing, there are bubble and stripe formations - reduce dosing.
In case of under-dosing, water drops remain on the washed items - increase dosing.

10.2 Noise level

Work place noise level LpA £ 70 dB

10.3 Data reg. the electrical and hydraulic equipment

See attached technical sheet

10.4 Dimensions, technical data, installation instructions

See attached technical sheet
10.5 EC-/EU–Declaraton of Conformity
See separate EC-/EU-Declaration of Conformity
11

Non-ionizing radiation

Non-ionizing radiation is not produced intentionally but unfortunately comes about due to
electrical operating equipment (e.g. electrical motors, high-voltage cables and magnetic
coils). In addition the machine has no strong permanent magnet. There is a high possibility
of eliminating the influence of active implants (e.g. pacers, defibrillators) by maintaining a
safety distance of 30 cm (distance of the field source to the implant).
21 / 44
9625762