Operating instructions EcoStar 545 D-M
Datei:1_EcoStar545D-M_9654091_Betriebsanleitung_EN_2007-07.doc
MEIKO Maschinenbau GmbH & Co. KG, Postfach 2040, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1174
11.1 General description of the dishwashing machine
11.1.1 Execution
Square basket appliance with stationary basket
11.1.2 Wash principle
The appliance has one wash and one final rinse cycle.
The temperature regulator keeps the wash temperature. A centrifugal pump circulates
the water out of the wash tank into the wash nozzles. The water jets reach the items to
be washed out of differing directions. Therefore an even washing result can be
guaranteed.
The washing cycle is followed by the fresh water final rinse. The items are rinsed via a
separate nozzle system with hot fresh water 80 - 83° C. Thus heating up the items for
the following drying process. At the same time the final rinse water serves for the
regeneration of the wash water, the level of soil of the wash water thus being reduced.
11.1.3 Detergent dosage
The detergent dosing unit (option) is designed for the automatic adding of liquid, alkaline
detergent into the wash water.
The detergent is transported out of the container into the wash tank by means of a hose
line. The dosing unit is self-priming. The dosing is effected during each filling cycle and
at the beginning of each programme cycle using timer control.
Normally, a dosing of approx. 2 ml of detergent per liter of tank water is the correct
concentration. This can be increased/reduced acc. to the water quality, items to be
washed and degree of soiling to 5 ml/l or to1 ml/l.
11.1.4 Rinse aid dosing
The rinse aid dosing unit is designed to automatically add liquid final rinse aid into the
fresh water.
The rinse aid is transported out of the container into the fresh water supply line by means
of a hose line. The dosing unit is self-priming. The dosing takes place during each filling
cycle.
The correct dosing results in a smooth, even water film.
In case of overdosing, there are bubble and stripe formations - reduce dosing.
In case of under-dosing, water drops remain on the washed items - increase dosing.
11.2 Noise level
Work place noise level LpA
11.3 Data reg. the electrical and hydraulic equipment
See attached technical sheet
11.4 Dimensions, technical data, installation instructions
See attached technical sheet
Update: 2007-07-23
W e reserve the right to change execution and construction!
70 dB
9645091
19/30