Attenuation Settings

Attenuation settings describe type and dB settings for walls within a floor plan.
To edit the wall settings and select a color for wall types within the VisualRF UI, navigate to the Wall Attenuation
Settings section and select the pencil icon next to the setting that you want to edit. The VisualRF default
attenuations and dB values are described in
276 | Using VisualRF
Default
Description
data samples).
If so (Yes to question above), then recalculate the client device's location based
l
on the samples received.
If not (No to the question above), then wait until the number of sample setting is
l
met before recalculating. If the number of samples is never met, wait until the
maximum timer (default is 120 seconds) and then recalculate.
4
See definition above.
500/2000
3
This timer determines how often to calculate the location of printers. Taken with the
data samples the calculation acts as follows:
After the minimum timer (default is 120 seconds), check to see if the number of
l
data samples received from all APs that hear this client are greater than or
equal to the number of samples setting for legacy laptop devices (default of 3
data samples).
120/480
If so (Yes to question above), then recalculate the client device's location based
l
on the samples received.
If not (No to the question above), then wait until the number of sample setting is
l
met before recalculating. If the number of samples is never met, wait until the
maximum timer (default is 480 seconds) and then recalculate.
3
See definition above.
This timer determines how often to calculate the location of rogues. Taken with the
data samples the calculation acts as follows:
After the minimum timer (default is 500 seconds), check to see if the number of
l
data samples received from all APs that hear this client are greater than or
equal to the number of samples setting for legacy laptop devices (default of 3
data samples).
500/2000
If so (Yes to question above), then recalculate the client device's location based
l
on the samples received.
If not (No to the question above), then wait until the number of sample setting is
l
met before recalculating. If the number of samples is never met, wait until the
maximum timer (default is 2000 seconds) and then recalculate.
3
See definition above.
90/360
3
Table
141.
Dell PowerConnect W-AirWave 7.6 | User Guide