Location Calculation Timer Settings - Dell PowerConnect W-AirWave 7.6 User Manual

Hide thumbs Also See for PowerConnect W-AirWave 7.6:
Table of Contents

Advertisement

Location Calculation Timer Settings

To tune the frequency for calculating device locations within the VisualRF UI, navigate to the Location Calculation
Timer Settings section. The available settings are described in
Table 140:
Location Calculation Timer Settings Section of VisualRF > Setup
Setting
Legacy Laptop
Min/Max (sec)
Legacy Laptop Number
of Samples
Laptop Min/Max (sec)
Laptop Number of
Samples
Phone Min/Max (sec)
Phone Number of
Samples
RFID Min/Max (sec)
Dell PowerConnect W-AirWave 7.6 | User Guide
Default
Description
This timer determines how often to calculate the location for legacy laptop devices.
Taken with the data samples the calculation acts as follows:
After the minimum timer (default is 90 seconds), check to see if the number of
l
data samples received from all APs that hear this client are greater than or
equal to the number of samples setting for legacy laptop devices (default of 3
90/360
data samples).
If so (Yes to question above), then recalculate the client device's location based
l
on the samples received.
If not (No to the question above), then wait until the number of sample setting is
l
met before recalculating. If the number of samples is never met, wait until the
maximum timer (default is 360 seconds) and then recalculate.
3
See definition above.
This timer determines how often to calculate the location for laptop (non-legacy)
devices. Taken with the data samples the calculation acts as follows:
After the minimum timer (default is 90 seconds), check to see if the number of
l
data samples received from all APs that hear this client are greater than or
equal to the number of samples setting for legacy laptop devices (default of 3
90/360
data samples).
If so (Yes to question above), then recalculate the client device's location based
l
on the samples received.
If not (No to the question above), then wait until the number of sample setting is
l
met before recalculating. If the number of samples is never met, wait until the
maximum timer (default is 360 seconds) and then recalculate.
3
See definition above.
This timer determines how often to calculate the location of phones. Taken with the
data samples the calculation acts as follows:
After the minimum timer (default is 60 seconds), check to see if the number of
l
data samples received from all APs that hear this client are greater than or
equal to the number of samples setting for legacy laptop devices (default of 3
data samples).
60/240
If so (Yes to question above), then recalculate the client device's location based
l
on the samples received.
If not (No to the question above), then wait until the number of sample setting is
l
met before recalculating. If the number of samples is never met, wait until the
maximum timer (default is 240 seconds) and then recalculate.
3
See definition above.
This timer determines how often to calculate the location of RFIDs (such as devices
with tag readers for tracking). Taken with the data samples the calculation acts as
follows:
30/120
After the minimum timer (default is 30 seconds), check to see if the number of
l
data samples received from all APs that hear this client are greater than or
equal to the number of samples setting for legacy laptop devices (default of 4
Table
140:
Using VisualRF | 275

Advertisement

Table of Contents
loading