EPSON Stylus Pro 9500
CR ENCODER SENSOR INSTALLATION POSITION ADJUSTMENT
This adjustment is performed to install the CR encoder sensor in the
appropriate position with respect to the CR linear scale.
The CR encoder sensor used in the Stylus Pro 9500
n
differs in its shape from the CR encoder sensor used
in the Stylus Pro 9000, when using tool #766 in this
adjustment, it should be used only after confirming
the shape of the CR encoder sensor.
Figure 5-19. CR Encoder Sensor Shape
1. Loosen the 2 CR encoder sensor installation screws and set tool #F766
between the CR encoder sensor and CR guide rail as shown in the figure
below.
2. Push the CR encoder sensor toward the tool lightly, then tighten the 2 CR
encoder installation screws.
Adjustment
New CR Encoder
Sensor
Adjustment Steps
CR encoder sensor
assembly installation
screws
Figure 5-20. CR Encoder Sensor Installation Position Adjustment
Revision A
Exclusive tool #F766
210