4.2.3.9 Removing the sensors
1. Remove the L/R side cover.(See 4.2.1.3)
2. To remove the interlock switch (R), disconnect the cable from the
connector CN13 on the relay board.
3. Remove the two screws (CP(W2) M3x6) securing the interlock switch
mount plate to the side frame, and remove the interlock switch (R) together
with the mount plate.
Figure 4-43. Interlock Switch (R) removal
Disassembly & Assembly
CN13
Disassembly Flow
4. To remove the interlock switch (L), disconnect the cable from the
connector CN27 on the C277MAIN board.
5. Remove the two screws (CP(W2) M3x6) securing the interlock switch
mount plate to the side frame, and remove the interlock switch (L) together
with the mount plate.
Figure 4-44. Interlock Switch (L) removal
When the interlock switch has been removed, the following
adjustment should be made.
n Cover R/L Sensor Assembly Adjustment (Interlock
switch position adjustment) (Self-diagnostic Mode)
Refer to page 215.