5. Slide the CR relay board mounting plate toward the front of the printer.
6. Remove the 2 screws (CP(W2) M3 x 6) each, then remove the HP sensor
and encoder from the back of the CR relay board mounting plate.
CR HP Sensor
CR HP Sensor
Installation Screws
Figure 4-51. Fig. 4-51 Removing the CR HP Sensor and Encoder
If you have removed the CR encoder sensor, the following
adjustment is necessary.
n CR encoder sensor installation position adjustment.
Refer to page 210.