16. Take out the 3 screws (CP(W2) M4 x 6; 2 pcs., CP(W2) M3 x 6; 1 pc.)
holding the maintenance assembly (cap assembly, pump assembly, pump
motor, CR lock solenoid), then pull the maintenance assembly out
gradually toward the front of the printer. Two of the screws holding the
maintenance assembly are located on the back side of the maintenance
assembly, as shown in the figure below.
Figure 4-84. Removing the Maintenance Assembly (1)
Figure 4-85. Removing the Maintenance Assembly (2)
Disassembly & Assembly
17. If the maintenance assembly is gradually pulled out of the printer
mechanism, the pump motor on the maintenance assembly will catch on
the bottom of the front cover, so at this point, rotate the maintenance
assembly clockwise as shown in the figure below then pull the
maintenance assembly out. At this time, the front cover should be closed
and fastened in place with adhesive tape.
Figure 4-86. Removing the Maintenance Assembly (3)
Figure 4-87. Removing the Maintenance Assembly (4)
Disassembly Flow