Lexmark X642e Service Manual page 61

Hide thumbs Also See for X642e:
Table of Contents

Advertisement

Service error codes (9xx.xx) (continued)
Error
Sub
Display text
code
codes
922
.14
Hot roll timed out in
trying to reach the final
lamp detection
temperature. Fuser
page count between
100,000 and 199,999.
922
.15
After hot roll lamp
detection, did not roll
over to steady state
control in time. Fuser
page count between
100,000 and 199,999.
922
.16
Hot roll did not reach
operating temperature in
time (new enhanced
control). Fuser page
count between 100,000
and 199,999.
922
.17
Fuser has taken too long
to reach desired
temperature after
increasing interpage
gap. Fuser page count
between 100,000 and
199,999.
922
.22
Hot roll took too long to
reach the beginning
lamp detection
temperature. Fuser
page count between
200,000 and 299,999.
922
.23
Hot roll reached final
lamp detection
temperature but took
longer than largest time
in lookup table. Fuser
page count between
200,000 and 299,999.
922
.24
Hot roll timed out in
trying to reach the final
lamp detection
temperature. Fuser
page count between
200,000 and 299,999.
922
.25
After hot roll lamp
detection, did not roll
over to steady state
control in time. Fuser
page count between
200,000 and 299,999.
Description
• Low wattage or incorrect lamp.
• Bad thermistor, circuit, or
cabling.
• Fuser not receiving sufficient AC
power.
• Poor supply line voltage.
The control code has been lost.
• Low wattage or incorrect lamp.
• Bad thermistor, circuit, or
cabling.
• Fuser not receiving sufficient AC
power.
• Poor supply line voltage.
• Low wattage or incorrect lamp.
• Bad thermistor, circuit, or
cabling.
• Fuser not receiving sufficient AC
power.
• Poor supply line voltage.
• Low wattage or incorrect lamp.
• Bad thermistor, circuit, or
cabling.
• Fuser not receiving sufficient AC
power.
• Poor supply line voltage.
• Low wattage or incorrect lamp.
• Bad thermistor, circuit, or
cabling.
• Fuser not receiving sufficient AC
power.
• Poor supply line voltage.
• Low wattage or incorrect lamp.
• Bad thermistor, circuit, or
cabling.
• Fuser not receiving sufficient AC
power.
• Poor supply line voltage.
The control code has been lost.
Action
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Go to
"922.xx—Cold fuser check"
on page
2-134.
Diagnostic information
7002-xxx
2-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

X644eX646e

Table of Contents