Configuration ID

The two configuration IDs are used to communicate information about certain areas of the printer that cannot be
determined using hardware sensors. The configuration IDs are originally set at the factory when the printer is
manufactured, however, the servicer may need to reset Configuration ID 1 or Configuration ID 2 whenever you
replace the system board. The IDs consist of eight hexadecimal characters, including 0 through 9 and A
through F.
Note: When the printer detects a Configuration ID that is not defined or invalid, the following occurs:
The default standard model Configuration ID is used instead.
Configuration ID is the only function available in DIAGNOSTICS.
Unless the menu is in DIAGNOSTICS, Check Config ID displays.
To set the configuration ID:
1.
Touch
to select PRINTER SETUP from the Diagnostics Menu.
2.
Touch
to select Configuration ID.
3.
Touch the keyboard icon to display a keyboard with 1 through 0 and a through f. The current values for
Configuration ID 1 and Configuration ID 2 are displayed.
Use keys to type the numbers for the two configuration IDs.
Use the left arrow to move over a digit from the right of the number toward the left.
When the numbers are correct, touch Submit.
If you have a question, touch the question mark icon.
To exit without changing the numbers, touch Back.
Note: Be sure to touch Submit, or the number will not be changed.
Submitting Selection displays, followed by the value for Configuration ID 1.
Note: If Invalid ID appears, the entry is discarded, and the previous Configuration ID 1 is displayed on
the screen.
If the process is successful, Submitting Selection appears on the display, followed by the current
value for Configuration ID 2.
4.
Restart the printer.

Edge to Edge

When this setting is On, the text and graphics are shifted to the physical edges of the paper for all margins.
When the setting is Off, the normal margins are restored.

Parallel strobe adjustment (Par x Strobe Adj)

This setting adjusts the amount of time the strobe is sampled in order to determine if the valid data is available
on the parallel port. The range of values are from -4 to 6, and the default is 0 for Par S Strobe Adj,
Par 1 Strobe Adj, and Par 2 Strobe Adj. After adjustment of 1 increment, the strobe samples 50 ns longer.