FRU
5
First scan sensor—
electrical checks
Action
Turn the power off, and reconnect CN10 to the motor driver card.
Measure the voltages in the table below with the sensor in normal
operation (sensor closed) and with the sensor open (paper over the
sensor).
First scan sensor
Connector CN10 (motor driver card)
Pin number
Sensor closed (uncovered)
CN10—Pin 7
CN10—Pin 8
+0.03 V dc
CN10—Pin 9
+5.0 V dc
Note: All voltages are approximate values.
If the voltages are incorrect, replace the first scan sensor. If this does
not fix the problem, replace the complete ADF assembly. See
complete assembly removal" on page
Note: Whenever the complete ADF assembly is replaced, it is
necessary to perform scanner registration. See
registration" on page
4-4.
Sensor open (covered)
+0 V dc
+5.0 V dc
+5.0 V dc
4-15.
"Scanner
Diagnostic information
7002-xxx
0 V dc
"ADF
2-103