Envelope feeder service check

Service tip: Check the envelope feeder paper path for any debris, pieces of envelope and so on. If any other
options are installed make sure they are operating normally. If only the envelope feeder is failing to operate
correctly, continue with this service check, otherwise verify the interconnect card is functioning properly.
Service tip: The envelope feeder receives its +5 V dc operating voltage from the +24 V dc bulk at J1-7. If
+24 V dc is not present at J1-7, tray 1 is the only tray that is recognized.
Printer does not recognize the envelope feeder as an attached input option
FRU
1
Envelope feeder
2
Front autoconnect on
printer
3
Autoconnect on the
envelope feeder
Touchscreen displays
requested—POST incomplete
FRU
1
Pass thru sensor
Action
Make sure the envelope feeder is correctly installed and mated to the
autoconnect at the front of the printer.
Check the connector for signs of damage to the connector or
contacts. If you find damage, replace the damaged cable/connector
assembly. Remove the envelope feeder and check the voltages at the
autoconnect on the front of the printer. If incorrect, check the system
board. If correct, reinstall the envelope feeder and continue with
step 3.
Check for damage to the connector or contacts. If you find damage,
replace the damaged cable/connector assembly. Disconnect the
autoconnect cable at J1 on the envelope system board and measure
the following voltages:
• J1-3 measures +5 V dc
• J1-5 measures +5 V dc
• J1-7 measures +24 V dc
If any of the voltages are incorrect, replace the autoconnect cable/
connector. If the voltages are correct, replace the envelope system
board.
immediately when envelope feed is
260.xx Paper Jam
Action
Check for any debris or pieces of envelope over the pass thru sensor.
Check for correct installation of the pass thru sensor flag. Make sure
the sensor cable is attached to the envelope system board. Perform
an envelope feeder sensor test to check both the sensor and sensor
flag.
Note: It may be necessary to use a small tool to actuate the sensor
flag because it is located under the front cover. Be careful not to
damage the flag.
If the test fails, check the flag for damage or binds. If incorrect,
replace the flag. If the flag is operating correctly, check the voltage at
J3-3. The voltage measures approximately +5 V dc. If incorrect,
replace the envelope system board. If correct, check the voltage at
J3-2. The voltage changes from 0 to +5 V dc when the flag is moved
in and out of the sensor. If incorrect, replace the sensor assembly. If
this does not fix the problem, replace the envelope system board.
7002-xxx
2-129