Fuser exit sensor removal

1.
Remove the fuser. See
2.
Disconnect the fuser exit cable (A) from the fuser control board.
3.
Remove the screw (B) securing the cover containing the fuser exit sensor, flag, and spring.
4.
Release the two clips (C) holding the sensor in the bracket.
5.
Unplug the fuser exit sensor cable from the sensor.
Installation
1.
Move the fuser exit sensor flag out of the way to clip the sensor securely into the cover.
2.
Connect the fuser exit sensor cable.