Extreme Networks ExtremeWare Command Reference Manual page 1563

Version 7.0.0
Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

To configure a BlackDiamond switch to run diagnostics on an MSM64i at boot-up, use the following
command:
config diagnostics [extended | fastpost | normal | off]
Example
The following command runs extended diagnostics on the module in slot 3 of a BlackDiamond chassis:
run diagnostics extended slot 3
A warning is displayed about the impact of this test, and you have the opportunity to continue or
cancel the test.
Running extended diagnostics will disrupt network traffic on the system.
Extended diagnostic will also execute Packet Memory Scan........
WARNING:
Device may be taken offline. To prevent this
first configure "sys-health-check auto-recovery online"
Are you sure you want to continue?
y
History
This command was first available in ExtremeWare 6.1.5.
The command was modified to support the MPLS module in an ExtremeWare IP Technology Services
Release based on ExtremeWare v6.1.8b12.
The command was modified to support MSM64i modules in ExtremeWare 6.1.9.
The command was modified to support Alpine and Summit switches in ExtremeWare 6.2.
Platform Availability
This command is available on "i" series switches.
ExtremeWare Software 7.0.0 Command Reference Guide