4. Disconnect the Load Cell harness.
5. Move the Load Cell/Spider Assembly into position on the opposite
side of the scanner cavity and re-install the original screws. Torque
the screws evenly to 50 in-lb.
Product Flow
Product Flow
Load Cell/Spider
Assembly
6. Route the Load Cell harness, re-bending it as indicated on the har-
ness, and reconnect.
7. Orient the EAS Antenna in the position indicated by
then route the antenna cable down through the unit's side. Securely
attach the antenna using the screws provided.
8. Connect the antenna cable to the EAS Controller Box.
9. Re-install the platter.
The scale must be recalibrated upon completion of this proce-
dure, or upon completion of installation.
DO NOT touch EAS Antenna coils inside of housing when in operation. Coils
generate over 500 VDC when activated.
This completes the EAS Single-Antenna location swapping procedure.