Product Reference Guide
Specifications for scale capacity, settling time, minimum and maximum
static weight, zeroing, and warm-up time are given below. For more infor-
mation regarding the topic:
tion and Maintenance
Rated Weight Capacity
The scale's operational weight capacity is:
30.00 pounds, displayed in 0.01 increments
OR
15.000 kilograms
Minimum Increment
The minimum weight that can be accurately measured by the scale is 0.02
lb. (0.005 kg).
Maximum Static Weight (Overload)
A maximum static weight of 150 pounds (68 kg) can be sustained by the
scale without incurring damage or degrading performance.
Automatic Zero Maintenance
The scale's software constantly monitors and adjusts the Zero point as
long as the deviation is within acceptable limits
any debris accumulation or removal. During power-up, the scale automat-
ically re-zeros after verifying that all subsystems are functional. Addition-
ally, the scale may be manually "zeroed" by pushing the Scale Zero Push
Button located on the top of the vertical enclosure.
1. The scale can also be set for 9.99 kg max.
2. Acceptable limitis of deviation are set at -0.2 to +0.6 pounds (-0.078kg to 0.23kg), which is -0.67 to
+2.0% of total capacity.
Proper Weighing Technique
chapter of this manual.
1
, displayed in 0.005 increments.
Physical Parameters
, refer to the
Opera-
2
, while compensating for
1-7