Single Cable RS-232 RTS CTS Selection

6-112
Specifies how RTS and CTS are used to control the data flow. RTS is con-
trolled by the Scanner and can be continuously held high/low, or can be
asserted during label transmission. The scanner looks at CTS, as the con-
figuration values state, to determine when to send label data.
Choices are:
Option 0 = RTS is held in low state and CTS is ignored
Option 1 = RTS is held in high state and CTS is ignored
Option 2 = Assert RTS and wait for CTS to be asserted
Option 3 = Assert RTS and ignore CTS
Option 4 = RTS held low, wait for CTS to be asserted
Option 5 = RTS held high, wait for CTS to be asserted
To set this feature:
1. Scan the SWITCH bar code.
2. Scan a bar code below or on the following pages representing the
desired option. You'll need to cover any unused bar codes, as well as
facing pages to ensure that the scanner reads only the bar code you
intend to scan.
3. Complete the programming sequence by scanning the SWITCH
bar code.
RTS CTS SELECTION = OPTION 0
RTS CTS SELECTION = OPTION 1
®
Magellan
9500