Manual EAS Deactivation Push Button
PRESS
DURATION
Manually initiates EAS
a
Momentary
deactivation
Allows scanner to resume
3 Seconds upon
function despite EAS sys-
EAS error
tem failure (non-fatal
error)
a. For use in Coupled Mode only
b. "Downstream" in this case is defined as being the downstream side of the scan window from
the direction of product flow, or scanning direction.
c. If the EAS failure corrects itself, blinking will stop and the EAS LED will turn green.
A-8
Using the programming bar codes contained in the Product Refer-
ence Guide (PRG) the button can be configured to operate always,
or only function when the scanner is enabled.
FUNCTION
COMMENT
Place the item with the EAS tag downstream
horizontal scan window and push the button.
EAS Failure Mode is indicated
- EAS LED blinks ON/OFF red, scanning disabled.
- FRU Status LED Indicator blinks '9'
- Error tone is sounded for one second
Upon pressing the button for 3 seconds, the scan-
ner will sound 3 high-pitched beeps, then resume
scan function. The EAS LED and FRU Status LED
will continue blinking as above, but at a slower rate
until EAS system function is restored.
b
of the
c
by:
®
Magellan
9500