SELFTEST
START
Does the
7-segment
display show
0
?
YES
No interface selected
(Null Interface).
Select an interface.
Go to EAS System
flowchart
Does the
7-segment
display show
9.
?
4-8
Figure 4-3. Problem Isolation: Selftest
Does the
YES
NO
7-segment
display show
1.
?
NO
Does the
7-segment
display show
2. or 3.
?
NO
Does the
7-segment
display show
4. or 5.
?
NO
Does the
7-segment
display show
7 or A.
?
NO
Does the
NO
7-segment
display show
8.
?
Does the
7-segment
display show
C.
?
NO
Unit passes Selftest
Scan the Factory
Defaults bar code in
Section 6 to enable the
default configuration
file. Restart the unit.
YES
Call Tech Support
Error code 4. indicates a failed
horizontal VLDM (laser) assembly,
while 5. indicates a failed vertical
VLDM. If configured to do so 1 , the
YES
scanner will remain operational
with only one of these lasers until
the unit can be serviced. If both
lasers have failed, the unit will no
longer function.
YES
Call Tech Support
YES
Go to Remote Display
flowchart
For this error, the Remote Display
may also show -0- or an error (E__#).
YES
Go to Scale flowchart
1
Refer to the feature Laser Failure
Mode in Section 6.
Does the
YES
7-segment
display show
1.
?
NO
®
Magellan
9500

Hide quick links: