Codabar Minimum Label Length - Datalogic Magellan 9500 Product Reference Manual

With smartsentry
Table of Contents

Advertisement

Codabar Minimum Label Length

NOTE
6-244
This feature specifies the minimum allowable length of a Codabar label.
Length in this case includes start, stop or check and data characters, but
does not include full ASCII shift characters. This feature applies when Coda-
bar Length Control is set to variable-length decoding.
Minimum label length should be less than or equal to maximum label length.
To set this feature:
1. Scan the SWITCH bar code.
2. Scan the bar code,
below. You'll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.
3. Scan the appropriate digits from the keypad in Appendix C that rep-
resent the desired minimum label length. The selectable range for
this option is 03 to 50. Pad all single digit numbers with a leading
zero to yield a two-digit entry (03-50).
4. Complete the programming sequence by scanning the SWITCH
bar code.
SET CODABAR MINIMUM LABEL LENGTH
SET CODABAR MINIMUM LABEL LENGTH
®