IE 3000 Switch Cisco IOS Commands

alarm relay-mode

Use the alarm relay-mode global configuration command to set the alarm relay mode for the switch to
positive or negative. Use the no form of the command to set the alarm relay mode to the default mode.
Syntax Description
negative
Defaults
By default, the alarm relays are in positive mode when they are open. When there is no power to the
switch, all alarm relays are open. The alarm relays close when one or more alarm events are detected.
Command Modes
Global configuration
Command History
Release
12.2(44)EX
Usage Guidelines
Use this command to invert the behavior of the alarm relays. When the alarm relay mode is set to
negative, alarm relays are normally closed. When one or more alarm events are detected, the appropriate
alarm relay opens.
Examples
This example shows how to set the alarm relays to negative mode:
Switch(config)# alarm relay-mode negative
Related Commands
Command
alarm profile (global
configuration)
show alarm profile
show alarm settings
OL-13019-01
alarm relay-mode {negative}
no alarm relay-mode {negative}
Set the alarm relay mode to negative.
Modification
This command was introduced.
Description
Creates or identifies an alarm profile and enters alarm-profile configuration
mode.
Displays all alarm profiles or a specified alarm profile and lists the interfaces
to which each profile is attached.
Displays environmental alarm settings and options.
Cisco IE 3000 Switch Command Reference