Alarm Facility Power-Supply - Cisco IE-3000-8TC Command Reference Manual

Command reference
Hide thumbs Also See for IE-3000-8TC:
Table of Contents

Advertisement

Chapter 2
IE 3000 Switch Cisco IOS Commands

alarm facility power-supply

Use the alarm facility power-supply global configuration command to set the alarm options for a
missing or failing power supply when the system is operating in dual power-supply mode. Use the no
form of the command to disable the specified setting.
Syntax Description
disable
notifies
relay major
relay minor
syslog
Defaults
A power supply alarm message is stored but not sent to an SNMP server, to a relay, or to a syslog server.
Command Modes
Global configuration
Command History
Release
12.2(44)EX
Usage Guidelines
Power supply alarms are generated only when the system is in dual power-supply mode. When a second
power supply is connected, you must use the power-supply dual global configuration command to set
dual power-mode operation.
Before you use the notifies keyword to send alarm traps to an SNMP host, you need to set up an SNMP
server by using the snmp-server enable traps global configuration command.
Examples
This example shows how to set the power-supply monitoring alarm to go to the minor relay circuitry:
Switch(config)# alarm facility power-supply relay minor
Related Commands
Command
power-supply dual
show alarm settings
snmp-server enable traps
OL-13019-01
alarm facility power-supply {disable | notifies | relay {major | minor} | syslog}
no alarm facility power-supply {disable | notifies | relay {major | minor} | syslog}
Disable the power supply alarm.
Send power supply alarm traps to an SNMP server.
Send the alarm to the major relay circuitry.
Send the alarm to the minor relay circuitry.
Send power supply alarm traps to a syslog server.
Modification
This command was introduced.
Description
Sets the switch to operate in dual power-supply mode.
Displays environmental alarm settings and options.
Enables the switch to send SNMP notification for various trap types to
the network management system (NMS).
Cisco IE 3000 Switch Command Reference
alarm facility power-supply
2-7