Avaya Octel 200 Installation And Maintenance Manual page 424

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8-38
Installation and Maintenance Volume
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
72 Protocol Revision
Level Error
DATA-1 =
Digital Networking
DATA-2 =
Local Protocol Revision Level
DATA-3 =
Remote Protocol Revision Level
DATA-4 =
Location number of Remote Location
. Control Bus
73
Error – VCU
shared RAM I/O
DATA-1 = Task Number
DATA-2 = 01
02
74 Gateway Timeout
error
DATA-1 = OctelAccess ID (the ID configured at the OctelAccess server)
75 Names Directory
Export error
DATA-1 =
ERROR CODE:
01 =
02 =
03 =
04 =
05 =
06 =
78. Network Message
Delivery Time
Out
Octel 200/300
S.4.1
Source
Namesend activity
Disable Namesend to the remote location.
Dependent on value in
Replace VCU. If error repeats, contact your
DATA-2.
technical support center.
VCU to CPU
CPU to VCU
Message server timed
The OctelAccess server is not responding.
out waiting for the
Check and bring up the OctelAccess server.
gateway poll.
Message server
Contact your technical support center.
detected error when
updating Names
Directory export file
or during export file
transfer.
NO DISK SPACE
READ ONLY VOLUME
ROOT DIRECTORY FULL
NO SYSTEM DEVICE
FILE CONTAINS BAD SECTORS
NOT A FILE SYSTEM DRIVE
Message server
Monitor network queue. Delivery attempt
determined that a
will retry; success is likely on the second or
network message
subsequent attempt. Use @LOCNAM
failed to be sent after
command to identify the network location.
the remote connection
DATA-1=
was established
because the protocol
DATA-2= Network location
between the two
servers did not
DATA-3= Message header number
complete correctly.
Remedy
0
Priority
1
3
3
2
1
PB60019−01