Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
34. Power-ON
Diagnostic Error
DATA-1
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
DATA-2
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
DATA-3
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
DATA-4
Bit 3:
Bit 2:
Bit 1:
Bit 0:
PB60019−01
Source
Selftest for CPU.
DATA-1 through
DATA-4 designate
errors found.
5 volts clean out of range
VCC out of range
A to D converter error
PIT1 error
Parity error
DRAM data error
Boot ROM checksum failure
Fatal CPU error
DMA page register error
Unexpected interrupt
PIT2 (8254) timing error
Temperature out of range
-12 volts clean out of range
-5 volts clean out of range
12 volts motor out of range
12 volts clean out of range
TDM crosspoint error
Modem failure
COM port failure
Watch Dog Timer failure
OCC error
Floppy Disk Controller error
Real Time Clock error
DMAC error
CODEC failure
BIC error
VCU error
Control Bus error
Remedy
Replace CPU. For OCC error, replace
OCC.