1. Connect telephone B to the modular-adapter position associated with port 1 of the Octel 200/300.
2. From telephone A, call the extension number associated with telephone B.
3. Answer telephone B, and perform a hookswitch flash or press the transfer key if available.
4. Does the PBX provide a stutter or solid dial tone after the hookswitch flash?
YES
NO
5. Enter the transfer initiate code, if any, then enter the extension number associated with telephone C.
6. After several ringbacks, perform a hookswitch flash or other key press, if required, to reconnect to
telephone A.
7. Did telephone C stop ringing? Were you reconnected to telephone A, which was on hold?
YES
NO
8. Make telephone C busy by taking it off-hook. Then repeat the test, starting with step 1 and calling a
busy extension instead of the ring-no-answer extension.
.
Test for Calls to the Intercept Extension (Attendant)
Verify that each extension can transfer a call to the intercept extension (attendant), as follows:
1. Connect telephone B to the modular-adapter position associated with port 1 of the Octel 200/300.
2. From telephone A, call the extension number associated with telephone B.
3. Answer telephone B, and perform a hookswitch flash or press the transfer key, if available. Press
(or the attendant's extension number), then hang up telephone B.
4. Did telephone A connect with the operator?
YES
NO
.
When all Octel 200/300 port extensions pass these tests, proceed by connecting the 25-pair cables to
the Octel 200/300 and test the message server for standard operation. The Octel 200/300 must
initialize each of the PBX ports. To verify that all the ports are initialized, at the @ prompt, enter
PS.
All ports should return IDL.
Test for Call to a Ring-No-Answer Extension
.
The extension to be called must have a valid first digit (a mailbox with this first digit must already
exist in the USER Table) or be entered in the USER Table as a mailbox (mailbox number same as
the extension number and a COS).
PB60019−01
If either tone is present, continue to step 5
'
Stop and correct the problem before continuing.
'
Connect telephone B to the next Octel 200/300 port extension and
'
continue until the extensions for each port are tested.
'
Determine the cause and correct the problem before continuing.
The extension number connected to telephone C should start with the same first digit as those
configured in the USER Table.
Continue test for all extensions, then proceed to the test in the next section.
'
Determine the cause and correct the problem before continuing.
'
Some PBXs do not allow a blind (unscreened) transfer to an attendant. If this is the case, do
not assign Attribute 15 — TRANSFER TO A RINGING EXTENSION, to the COS for this
mailbox.