Avaya Octel 200 Installation And Maintenance Manual page 66

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

Quick Reference Guide
Interfaces (continued)
Internal Modem
Works Serial Ports
Alarm Relay
Routine Maintenance
Air Filter Cleaning
Fan Inspection
System Protection
Overtemperature Shutdown
Disk Drive Spin Down
Power Supply Shutdown
Power Supply Unit Protection
Circuit Fuse
100−240 VAC Auto−
ranging PSU systems
120 VAC systems
230 VAC systems
DC systems
Overcurrent
Overvoltage
Overtemperature
Octel 200/300
S.4.1
Octel 200 Message Server Specifications
Bell 103/212A and CCITT V.22/CCITT V.22 bis. One per cabinet,
accessible from any telephony port.
Four RS-232C (2 DB9, 2 DB25) ports, rear access
DB9, rear access
At least yearly
At least yearly
<41F or >131F (<5C or >55C), automatic recovery
158F (70C), manual recovery
6 A
10 A
5 A
15 A
Four DC outputs, over current protection, automatic recovery
Power supply shut off
Power supply shut off, automatic recovery
Octel 200/300
Hardware
PB60019−01