Avaya Octel 200 Installation And Maintenance Manual page 396

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8-10
Installation and Maintenance Volume
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
05 =
06 =
0A = −5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
15:System Status
Error (continued)
0B = +5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
0C = DISK SHUTDOWN CAUSED BY OUT OF RANGE TEMPERATURE
16:Defect in hard
disk prompt area
DATA-1 =
00 =
01 =
02 =
DATA-2 =
LEAST SIGNIFICANT BYTE (Prompt number in HEX)
DATA-3 =
MOST SIGNIFICANT BYTE (Prompt number in HEX)
DATA-4 =
LANGUAGE SET # (1 TO N=n)
18. Data lost error.
Hard disk
number
DATA-1 =
LOGICAL DRIVE ID THAT FAILED TO REMAP SECTOR
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
20−22: DID System
Error
Octel 200/300
S.4.1
Source
+12 MOTOR VOLTAGE MEASUREMENT IS OUT OF RANGE
DATA-2 = SAME AS FOR 02
+5 BATTERY VOLTAGE MEASUREMENT IS OUT OF RANGE
DATA-2 = SAME AS FOR 02
DATA-2 = SAME AS FOR 02
Temperature or
Check DATA-1 for information pertaining
voltage out of range
to what is out of range and perform
corrective action.*
DATA-2 = SAME AS FOR 02
DATA-2 = REASON
01 =
SUCCESSFUL SHUTDOWN
02 =
FAILED TO SHUT DOWN
Defect in prompt area
Copy prompts from diskette to the hard
logged into Defect
disk, using the Floppy Backup Restore
List
procedure. If errors repeat, possible cause
could be HD or the VCU.
BOTH SYS DRIVES
SYS DRIVE 1
SYS DRIVE 2
Failure to attempt to
Replace hard disk with a spare provided by
relocate a bad sector
the manufacturer. If error continues, contact
on a disk. Data has
your technical support center.
been lost.
DID Diagnostics or
Refer to the DID/E&M Trunk Interface
configuration
manual for details.
problems
Remedy
+11.40 TO +12.60
+3.60 TO MINIMUM
−5.50 TO −4.50
+4.40 TO +5.50
41 F to greater than 131 F (5 TO 55 C.)
Priority
3
3
3
2