Avaya Octel 200 Installation And Maintenance Manual page 402

Hide thumbs Also See for Octel 200:
Table of Contents

Advertisement

8-16
Installation and Maintenance Volume
Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
02 =
03 =
04 =
05 =
33:Line Card
Hardware Error
The DATA-1 field specifies the type of error. DATA-2 and DATA-3 are data associated
with the error.
DATA-1 =
REPORTED STATUS
00 =
Octel 200/300
S.4.1
Source
DATA-2 =
3D =
DUAL PORT RAM READ/WRITE TEST FAILED
3E =
DUAL PORT RAM VERIFY TEST FAILED
3F =
STATIC RAM READ/WRITE TEST FAILED
40 =
STATIC RAM VERIFY TEST FAILED
41 =
UNEXPECTED INTERRUPT RECEIVED BY
COPROCESSOR
42 =
UNEXPECTED NMI RECEIVED BY
COPROCESSOR
43 =
COPROCESSOR EXECUTED A WILD JUMP
44 =
TIMED OUT WAITING FOR COPROCESSOR
READY
TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 1 TO
COMPLETE
TIMEOUT WAITING FOR COPROCESSOR DMA CHANNEL 2 TO
COMPLETE
COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 1
COPROCESSOR-DETECTED ERROR ON DMA CHANNEL 2
Error logged by
Contact your technical support center.
selftest when start
LSP reply was
received with either
an error status or an
unexpected OK status
(e.g., Slot is empty or
already reported
down)
START LSP REPLY RECEIVED WITH EITHER AN ERROR
STATUS OR AN UNEXPECTED OK STATUS
(e.g. slot is empty or already reported down.)
Remedy
Priority
3
PB60019−01

Advertisement

Table of Contents
loading

Table of Contents