Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
68 BIC Error
DATA-1 =
01 BIC read error (chip bad or missing).
DATA-1 =
02 BIC checksum error
DATA-2 =
Computed checksum.
DATA-3 =
Checksum stored in BIC.
69 VCU Software
port-controller
error
DATA-1 =
VCU software logical port with error status.
DATA-2 =
Currently active port-control-block for port-block 0 or 1.
DATA-3 =
Port block status.
Bit 0
Bit 1
Bit 2
Bit 3
70 Control Bus error
on a DSP-based
card
DATA-1 =
03 Timeout on an ISDN request
04 Timeout on a DTIC request
05 Timeout on a DPNSS request
06 Timeout on a QSIG request
DATA-2 =
Indicates the message type for which the time out occurred.
DATA-3 =
User Number, if applicable.
71 High Speed Link
Monitor Error
DATA-1 = Location number for which logged
DATA-2 = Sub-type, the possible values are as follows:
1 = continuous downtime exceeded system parameter 267
2 = cumulative downtime exceeded system parameter 268
3 = Number of times down exceeded system parameter 269
DATA-3 = Unused
DATA-4 = Unused
PB60019−01
Source
Dependent on value in
Replace CPU card.
DATA-1.
Error detected with
Contact your technical support center.
controller.
= Parity error
= Direction error
= Request timing error
= Port operation complete
Error in Control Bus
Replace the DSP-based card. If error
I/O between CPU and
repeats, call your technical support center.
card.
The Digital
Check remote location to see if digital
Networking
networking is up. Follow troubleshooting
high-speed link is
guidelines in the Networking volume,
down more than the
Digital Networking chapter
maximum configured
in System Parameters
267–269. An error is
logged per location.
System Errors and Traffic Pegs
Remedy
.
Octel 200/300
8-37
Priority
2
1
3
3
3
S.4.1

Advertisement

Table of Contents
loading