Table 8-2 Hardware Error Types and Remedies (continued)
Error Type:Name
38. Disk Defect Boot
Region
DATA-1 =
LOGICAL DRIVE ID WITH DEFECTIVE XBOOT
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
39. Disk Defect File
System Region
DATA-1 =
LOGICAL DRIVE ID WITH DEFECTIVE FILE SYSTEM
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
40. Non-Media Disk
Error
DATA-1 =
DRIVE ID AND SEVERITY INDICATION
01 =
02 =
03 =
04 =
05 =
06 =
81 =
82 =
83 =
84 =
85 =
86 =
DATA-2 =
SCSI SENSE KEY
DATA-3 =
SCSI SENSE CODE
DATA-4 =
NOT USED
PB60019−01
Source
Defect in secondary
Attempt to reload the software code from
bootstrap (Xboot)
the floppy diskette to the hard disk. If error
region
repeats, replace the hard disk indicated in
DATA-1. If error repeats again, call your
technical support center.
Defect in file system
Attempt to reload the software code from
region of a system
the floppy diskette to the hard disk. If error
disk
repeats, replace the hard disk indicated in
DATA-1. If error repeats, call your
technical support center.
Non-media disk error
Call your technical support center to have
information interpreted.
NON-FATAL ERROR, DRIVE 1
NON-FATAL ERROR, DRIVE 2
NON-FATAL ERROR, DRIVE 3
NON-FATAL ERROR, DRIVE 4
NON-FATAL ERROR, DRIVE 5
NON-FATAL ERROR, DRIVE 6
FATAL ERROR, DRIVE 1
FATAL ERROR, DRIVE 2
FATAL ERROR, DRIVE 3
FATAL ERROR, DRIVE 4
FATAL ERROR, DRIVE 5
FATAL ERROR, DRIVE 6
System Errors and Traffic Pegs
Remedy
Octel 200/300
8-23
Priority
3
3
1
3
3
S.4.1