About Environmental Monitoring
The following example illustrates how to display the environment condition on WS-C4500X-32 with a
Supervisor Engine 7-E. The thresholds appear within parentheses.
Switch> show environment
no temperature alarms
Module Sensor
------+--------------------------+--------------------+------------
1
1
1
1
1
1
2
2
Power
Supply
------
PS1
PS2
Power supplies needed by system
Power supplies currently available : 1
Chassis Type : WS-C4500X-32
Power consumed by backplane : 0 Watts
Switch Bandwidth Utilization : 0%
Supervisor Led Color : Green
Module
Module
Beacon Led Status : off
Fan trays needed by system
Fan trays currently available : 5
Chassis fan tray direction
Fantray 1 : dir : FrontToBack
Fantray 2 : dir : FrontToBack
Fantray 3 : dir : FrontToBack
Fantray 4 : dir : FrontToBack
Fantray 5 : dir : FrontToBack
Fantray removal timeout : 30
Power consumed by Fantray : 30 Watts
Switch>

Displaying On Board Failure Logging (OBFL) information for 9000W AC

9000W AC power supplies support logging of voltage sag (input voltage drops below a certain input
threshold) and voltage surge (input voltage spikes above a certain input threshold) events.
Catalyst 4500 Series Switch, Cisco IOS Software Configuration Guide - Cisco IOS XE 3.9.xE and IOS 15.2(5)Ex
14-4
XPP
VFE
CPU
FPGA
Stub A
Stub B
Air inlet
Air outlet
Model No
Type
----------------
---------
none
--
PWR-C49X-750AC-R
AC 750W
1 Status Led Color
: Green
2 Status Led Color
: Green
Chapter 14
Temperature
42C (80C,90C,100C)
47C (80C,90C,100C)
46C (80C,90C,100C)
50C (80C,90C,100C)
34C (80C,90C,100C)
35C (80C,90C,100C)
31C (80C,90C,100C)
36C (80C,90C,100C)
Fan
Status
Sensor
-----------
-------
--
--
good
good
: 1
: 4
: FrontToBack
status : Good
status : Good
status : Good
status : Good
status : Good
Environmental Monitoring and Power Management
Status
ok
ok
ok
ok
ok
ok
ok
ok
Inline
Status
-------
--
n.a.