Juniper JUNOS OS 10.4 - FOR EX REV 1 Manual page 220

For ex series ethernet switches
Table of Contents

Advertisement

Complete Software Guide for Junos
116
®
OS for EX Series Ethernet Switches, Release 10.4
—(TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router,
all-lcc
reboot all T640 routers (or line-card chassis) connected to the TX Matrix router. On
a TX Matrix Plus router, reboot all T1600 routers (or line-card chassis) connected
to the TX Matrix Plus router.
all-members
—(EX4200 switches only) (Optional) Reboot all members of the Virtual
Chassis configuration.
—(Optional) Time at which to reboot the software, specified in one of the following
at time
ways:
—Stop or reboot the software immediately. This is the default.
now
—Number of minutes from now to reboot the software.
+minutes
—Absolute time at which to reboot the software, specified as year,
yymmddhhmm
month, day, hour, and minute.
—Absolute time on the current day at which to stop the software, specified
hh:mm
in 24-hour time.
in minutes
—(Optional) Number of minutes from now to reboot the software. This option
is an alias for the
at +minutes
lcc number
—(TX Matrix and TX Matrix Plus routers only) (Optional) On a TX Matrix router,
the number of a T640 router that is connected to the TX Matrix router. On a TX Matrix
Plus router, the number of a T1600 router that is connected to the TX Matrix Plus
router. Replace
number
local
—(EX4200 switches only) (Optional) Reboot the local Virtual Chassis member.
media (compact-flash | disk | removable-compact-flash | usb)
for next boot. (The options
routers only.)
—(EX Series switches only) (Optional) Reboot the boot media:
media (external | internal)
—Reboot the external mass storage device.
external
—Reboot the internal flash device.
internal
—(EX4200 switches only) (Optional) Reboot the specified member
member member-id
of the Virtual Chassis configuration Replace
9.
—(Optional) Message to display to all system users before stopping or
message "text"
rebooting the software.
other-routing-engine
—(Optional) Reboot the other Routing Engine from which the
command is issued. For example, if you issue the command from the master Routing
Engine, the backup Routing Engine is rebooted. Similarly, if you issue the command
from the backup Routing Engine, the master Routing Engine is rebooted.
option.
with a value from
through
0
removable-compact-flash
member-id
.
3
—(Optional) Boot medium
and
pertain to the J Series
usb
with a value from 0 through
Copyright © 2010, Juniper Networks, Inc.