Start Physical Disk Channel Blink

Description
This command identifies the expansion enclosures that are connected to a specific physical disk port by
turning on the indicator lights for the expansion enclosure that is connected to the physical disk port. Use
the stop physicalDiskChannel blink command to turn off the indicator lights on the expansion
enclosure.
Syntax
start physicalDiskChannel [(1 | 2)] blink
Parameters
Parameter
physicalDiskChannel

Start Physical Disk Channel Fault Isolation Diagnostics

Description
This command runs the physical disk channel fault isolation diagnostics and stores the results.
Syntax
start physicalDiskChannel [(1 | 2)]
controller [(0 | 1)] faultDiagnostics
testDevices=[(all | controller=(0 | 1) |
emms=[enclosureID1 slotID1, enclosureID2 slotID2... enclosureIDn slotIDn]
|
physicalDisks= (enclosureID1,slotID1... enclosureIDn,slotIDn)]
| (dataPattern=(fixed | pseudoRandom) |
patternNumber=[(0xhexadecimal | number)] |
maxErrorCount=integer | testIterations=integer |
timeout=timeInterval)
Parameters
Parameter
physicalDiskChannel
controller
360
Description
The identifier number of the physical disk channel
that you want to locate. Valid values for the
identifier number are 1 or 2. Enclose the identifier
number in square brackets ([ ]).
Description
The identifier number of the physical disk channel
that you want to locate. Valid values for the
identifier number are 1 or 2. Enclose the identifier
number in square brackets ([ ]).