Set Storage Array Redundancy Mode - Dell PowerVault MD3220 Cli Manual

Powervault modular disk storag arrays
Hide thumbs Also See for PowerVault MD3220:
Table of Contents

Advertisement

Parameters
Parameter
daysToNextLearnCycle Valid values are 0 through 7, where, 0 is immediately
day
time
NOTE:
You can set the learn cycle to occur only once during a seven-day period.
The time parameter selects a specific time that you want to run the learn cycle. If a
value is not entered, the command uses a default value of 00:00 (midnight). If the
day and time specified are in the past, the next learn cycle takes place on the next
possible day specified.

Set Storage Array Redundancy Mode

This command sets the redundancy mode of the storage array to either
simplex or duplex.
Syntax
set storageArray redundancyMode=(simplex | duplex)
Parameter
Parameter
redundancyMode
Description
and 7 is in seven days. The daysToNextLearnCycle
parameter takes place up to seven days after the next
scheduled learn cycle.
Valid values for the day parameter include the days of
the week. Setting the day causes the next learn cycle
to be scheduled on the specified day, after the
currently scheduled learn cycle.
The time in 24-hour format; for example 8:00 a.m. is
entered as 08:00. Nine o'clock p.m. is entered as
21:00, and 9:30 p.m. is entered as 21:30.
Description
Use simplex mode when you have a single RAID
controller module. Use duplex mode when you have two
RAID controller modules
Script Commands
215

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents