Introduction; Specifications; Functional; Wireless - Visonic PowerMax10-G2 Installer's Manual

Wireless intrusion and fire alarm system
Hide thumbs Also See for PowerMax10-G2:
Table of Contents

Advertisement

1. INTRODUCTION

The PowerMax10-G2 is a user and installer-friendly, 29-
zone fully-supervised wireless control system.
The system is designed to function in an appealing way to
the user and also offers features that make installers' life
easier than ever before:
EASY TO MAINTAIN
Alarm memory and trouble data are displayed upon
request.
Diagnostic test provides visual and audible indication of
the signal level of each detector.

2. SPECIFICATIONS

2.1 Functional

Zones Number: 28 wireless zones, 1 hardwired input.
Hardwired Zone Requirements: 2.2 kΩ E.O.L. resistance
(max. resistance of wires 220 Ω).
Zone
Types:
Interior
perimeter follower, delay 1, delay 2, 24h silent, 24h
audible,
fire,
non-alarm,
temperature and home/delay.
User Codes: 8 codes, 4 digits each (9999 different
combinations). Code 0000 is not allowed.
Control Facilities:
- Integral keypad
- PowerG / Code-Secure™ hand-held transmitters.
- Two way keypads.
- SMS commands via optional GSM/GPRS module.
- Remote control by telephone.
Note: For SIA CP-01 compliance, when using KF-234 PG2
an external siren must also be used.
Display: Single line, backlit 16-character LCD.
Arming Modes: AWAY, HOME, AWAY-INSTANT, HOME-
INSTANT, LATCHKEY, FORCED, BYPASS.
Alarm inhibited during a single arming period (swinger
stop) after: 1, 2, 3, alarm/tamper/fault, or not inhibited
(programmable / selectable).
Note: To comply with EN requirements, the swinger stop
should be set to 3.
Alarm Types: Silent alarm, siren alarm (future option) or
sounder (internal) alarm, in accordance with zone attributes.
Siren Signals: Continuous (intrusion / 24 hours / panic);
triple pulse - pause - triple pulse... (fire).
Siren (bell) Timeout: Programmable (4 min. by default).
Internal Sounder Output: At least 85 dBA at 10 ft (3 m).
Supervision: Programmable time frame for inactivity alert
Special Functions:
- Chime zones
- Diagnostic test and event log.
- Local and Remote Programming over Telephone, GSM
/GPRS connections.
- Calling for help by using an emergency transmitter.
- Tracking inactivity of elderly, physically handicapped and
infirm people.
Data Retrieval: Alarm memory, trouble, event log.
Real Time Clock (RTC): The control panel keeps and
displays time and date. This feature is also used for the log file
by providing the date and time of each event.
Compliance with U.S. Standards:
USA: (FCC) CFR 47part 15 and part 68, UL 1023, UL 985,
UL 1635, UL 1637, SIA CP-01
Canada: RSS 210, ULC S545-02, ULC C1023,CSA
C22.2#205
D-302756
follower,
interior,
perimeter,
emergency,
gas,
Remote control from distant telephones.
Event log stores and displays information.
Upload / download from distant computer via telephone
line or cellular modem.
QUICK PROGRAMMING
Simple programming logic, fully menu driven.
Multiple-choice selection of options for each parameter.
Unequivocal visual prompts.
Installer access to the user menu.
Compliance with European CE Standards:
The PowerMax10-G2 has been certified to EN 50082-1,
EN301489-3,7,
EN50130-4, EN50130-5, EN50131-3, EN50131-6 tested by
the Dutch testing and certification body Telefication B.V.
The PowerMax10-G2 is compatible with the RTTE
requirements - Directive 1999/5/EC of the European
flood,
Parliament and of the Council of 9 March 1999.
According to the European standard EN50131-1, the
PowerMax10-G2 security grading is 2 – "low to medium
risk" and environmental classification is II – "indoor general"
and the power supply type is A.
GSM standards:
Europe: Complies with CE standards 3GPP TS 51.010-1,
EN 301 511, EN301489-7
USA: CFR 47 Part 22 (GSM850) and Part 24 (GSM 1900).
EMC standard: CFR 47 Part 15.

2.2 Wireless

Operating Frequencies (MHz): 315 (in USA & Canada),
433.92,
868.95
requirement in the country of use.
Receiver Type: Super-heterodyne, fixed frequency
Receiver Range: 600 ft (180 m) in open space
Antenna Type: Spatial diversity
Coding: PowerG and/or CodeSecure™

2.3 Electrical

External AC/AC adapter:
• Europe: 230VAC 50Hz input, 9VAC 700mA output.
• USA: 120VAC 60Hz input, 9VAC 1000mA output.
Current Drain: Approx. 70 mA standby, 1600 mA peak at
full load.
Minimum battery voltage: 4.8V
Note: For CE compliance the battery backup period shall
exceed 12 hours.
Backup Battery Pack: 4.8V 1300 mAh, rechargeable
NiMH battery pack, p/n GP130AAM4YMX, manufactured
by GP or equivalent.
Note: For compliance with UL standards the battery
backup period shall exceed 24 hours.
Backup Battery Pack: 4.8V 2200 mAh, rechargeable
NiMH battery pack, p/n GP230AAHC4YMX, manufactured
by GP.
Battery Test: Once every 10 seconds.

2.4 Communication

Built-in Modem: 300 baud, Bell 103 protocol
Data Transfer to Local Computer: Via RS232 serial port
Report Destinations: 2 Monitoring Stations, 4 private
telephones.
Reporting Format Options: SIA, Pulse 4/2 1900/1400 Hz,
Pulse 4/2 1800/2300 Hz, Contact ID, Scancom.
Pulse Rate: 10, 20, 33 and 40 pps - programmable
Message to Private Phones: Tone
EN61000-4-6,
EN60950,
or
other
UHF
channel
EN300220,
per
local
3

Advertisement

Table of Contents
loading

Table of Contents