MVRP Commands
mvrp timer periodic-timer
Specifies the MVRP periodic-timer time interval for the dynamically registering VLANs on the switch.
mvrp {port slot/port [– port2] | linkagg agg_num [-agg_num2]} timer periodic-timer timer-value
Syntax Definitions
slot/port
agg_num
timer-value
Defaults
parameter
timer-value
Platforms Supported
OmniSwitch 6400, 6850, 6855, 6850E, 9000E
Usage Guidelines
•
Use default timer settings unless there is a compelling reason to change the settings. Modifying timers
to inappropriate values might cause an imbalance in the operation of MVRP.
•
To use the agg_num parameter, the link aggregate group must be created and enabled.
Examples
-> mvrp port 1/2 timer periodic-timer 1
-> mvrp port 1/2 timer periodic-timer 1
-> mvrp linkagg 3 timer periodic-timer 1
-> mvrp linkagg 3-6 timer periodic-timer 1
Release History
Release 6.4.3; command was introduced.
OmniSwitch CLI Reference Guide
The slot number for the module and the physical port number on that
module (e.g., 3/1 specifies port 1 on slot 3).
The number corresponding to the aggregate group.
Specifies the value of the Periodic Timer in seconds. The valid range is
between 1 to 2147483647 milliseconds.
default
1 second
June 2012
page 11-21